Features and Benefits
Superior Reliability
In a Modular Power System (MPS), each genset backs up the others in the system, so
critical loads get redundant protection. This built-in redundancy also allows individual units to be
taken off-line for routine maintenance while retaining coverage for critical circuits.
Scalability
With MPS or the
Gemini® Twin Pack,
Generac customers can purchase the system
they need today, and can add units quickly and easily as they are needed. There's no need to replace the system if future
power requirements exceed projections and no need to over-spend on a larger system that might never be fully utilized.
Flexibility
Generac's MPS system is based upon an assortment of proven and reliable gensets that are
paralleled to match power requirement up to 9000 kilowatts. MPS gensets are small enough to fit into spaces that
can't accommodate large units, and they are light enough for rooftop applications. Since MPS modules don't have to be
physically located together, you can better utilize available space. In addition, the space required for switchgear and large external
panel boards is eliminated by Generac's MPS.
Serviceability
MPS generators use high volume, high reliability over-the-road truck or industrial engines
that can be easily serviced by qualified diesel technicians. Maintenance items and replacement parts are relatively
inexpensive and readily available.
Available, Fast Delivery
MPS generators use readily available high volume engines. Larger engines used in generators
that produce more than 600 kW are often built as needed and in far fewer numbers. This makes them more costly to
manufacture and can extend delivery time by weeks or months. Because MPS systems are designed, manufactured and
warranted by Generac, customers can typically take delivery months faster than with competitive systems.
Closed Recovery Cooling System
This closed, pressurized system virtually eliminates the introduction of air
into the cooling system. Rust and fluid acidity are minimized, resulting in longer engine life.
Isochronous Governor
Constant speed control provides faster response to block loads and a more consistent output
frequency. All generators utilizing PowerManager® G-Series control systems feature an isochronous governor.
Vibration Isolation
Standard vibration isolators virtually eliminate transmission of vibration from
the unit to the mounting surface.
Automatic Alarms & Shutdowns
Generator functions are constantly monitored through a protective system that features
solid state circuitry for reliability and long life. NFPA 110 required warnings and alarms provide alerts for
a variety of safety and operational concerns. The system automatically shuts down in response to certain critical
conditions such as high engine temperature, low coolant level, etc. All generators utilizing PowerManager® control
systems meet NFPA 110 requirements for warnings, alarms and alerts.
Advanced Wire Harness Design with Waterproof Connectors
Our wire harness design assures reliable, repeatable interconnection between circuit components. Special
sealed connectors protect against moisture, dust and environmental damage.
Generac Manufactured Alternators
Our revolving field alternators are fully-insulated and self-ventilating.
They feature higher temperature Class H insulation, but are designed to operate at lower, Class F temperature
levels for longer life. Oversized alternators are available on many models for additional motor starting capacity.
Solid-State Sensing and Starting Control
Provides the ultimate in engine protection. The magnetic pickup senses overspeed, automatically
shuts down the engine, disconnects the starter motor and prevents re-engagement. The system also provides cyclic
cranking for improved starting reliability and cranking termination for starter motor protection.
Solid-State, Frequency Compensated Voltage Regulation (V/F)
Provides fast, optimized response to changing load conditions. Maximum motor starting capability is
assured by electronically torque-matching the surge loads to the engine.
Permanent Magnet Excitation (PME)
Provides sustained short circuit current for breaker coordination. Increases motor starting
capabilities and enhances performance when load-induced harmonics are present. Standard on 150 kW (except MQT models)
and larger. Optional on smaller gensets.
Easy To Service
All service points are located at the perimeter of the frame for easy access.
Superior Paint
Our textured, powder coat paint process provides consistent coverage and better bonding to seams and exposed edges providing durability and a long-lasting, tough finish.
UL-Listed
All Generac standby generators are UL 2200 listed and our transfer switches are UL 1008 listed. UL listing verifies the kilowatt ratings of our generators and is your assurance that Generac standby systems meet the highest safety standards.
Made in USA
Generac generators are made in the United States by Generac Power Systems Inc. We design and
manufacture all of the major components including the alternators, controls and enclosures. This unprecedented degree of
control ensures that Generac products are built to the highest standards for quality, reliability and durability.